MDA failure records: 1 unit at BFT_MLB · Jira failure rate 0.04% (1/2535).
SN PVW51C0164640071 — NTF / Under FA(UFA)
Analysis: flux residue on BFT2 fixture probes created poor electrical contact. Failure rate 0.05% (1/2222). Unit successfully retested at BFT1, confirming device integrity. Probe contamination identified and cleaned, restoring contact and enabling test passage. Corrective Action Implement mandatory fixture probe inspection and cleaning procedure before DVT line start-up. CM DRI: Adam. Preventive maintenance