MDA failure records: 3 units at VI2 · Jira failure rate 4.23% (3/71).
SN GVW62R01645500BU — WIP / Under FA(UFA)
SN GVW62R01645500AE — WIP / Under FA(UFA)
SN GVW62R01645500BL — WIP / Under FA(UFA)
Analysis: Failure Analysis Bright marks on RH concentrated at ACT 2#. Holder inspection revealed scraping risk at bottom and edges during device pick-and-place. Simulated placement confirmed bright marks on both sides of rear cover (1F/5T). Attachments 20261118-161313.jpg and 20261118-161324.jpg provide direct photographic evidence of surface marks with red-box annotations on RH components. Corrective Actio

PQA Mark

your own words — no sync and no AI writes here
PQA Label

Report Fields

Other Information

[Miramar_hq_vn][DVT_MAIN][FATP] multiple failures [other@VI2]...