Amara · 2026-11-13 20:22 · Miramar

Miramar dummy build — Quality Daily Status Report — Day 16 (2026-11-13)
=================

Data cut-off: 2026-11-13 14:00 (VN) Phase: dummy build

OVERALL STATUS: RED

  1. EXECUTIVE SUMMARY
  1. FACTORY DATA (cut off 2026-11-13 14:00 (VN))
    OBA:
    • Pre-seal: Cum. inspected 1,956 (▲ +44) pcs, passed 1,956 (▲ +44) pcs, pass rate: 100.00%.
    • Post-seal: Cum. inspected 27 pcs, passed 27 pcs, pass rate: 100.00%.
      SMT MLB Production Data:
    • Cumulative actual Input/Output: 31,480 / 31,436 (▲ +1,232) pcs. Cum. FPY: 99.86% vs target: 98.50%, Cum. RPY: 99.94% (▲ +0.1 pp).
    • Daily actual Input/Output: 1,232 / 1,229 (▼ -36) pcs. Daily FPY: 99.76% vs target: 98.50%.
      SMT AMPB Production Data:
    • Cumulative actual Input/Output: 12,000 / 11,814 (▼ -1,400) pcs. Cum. FPY: 98.45% vs target: 98.50% (▼ -1.2 pp), Cum. RPY: 99.12% (▼ -0.5 pp).
    • Daily actual Input/Output: 500 / 468 (▼ -110) pcs. Daily FPY: 93.60% vs target: 98.50% (▼ -5.9 pp).
      FATP Production Data:
    • Cumulative actual Input/Output: 15,210 / 15,010 pcs. Cum. FPY: 98.69% vs target: 97.50% (▼ -0.3 pp), Cum. RPY: 98.68% (▼ -0.3 pp).
    • Daily actual Input/Output: 1,180 / 1,163 (▲ +40) pcs. Daily FPY: 98.56% vs target: 97.50% (▼ -0.7 pp), Daily RPY: 99.81% (▲ +0.5 pp).
  1. OK2SHIP CRITICAL ISSUE(S) — 1 blocker, 0 critical
    Issue 1 : MIR-1042 — [Assembly] AMPB shield plate interferes with FATP test fixture
    Level: Blocker Risk: Red
    • Status: On-going DRI: Henry Zeng JIRA Ticket(s): MIR-1042
    • Description: During DVT FATP assembly in VN on 2026-11-12, the AMPB shield plate fouled the RF test fixture on 32 of 500 units; the line was stopped at 09:40 and the affected lot quarantined.
    • Customer Failure Mode: Shield plate sits 0.4 mm proud of the housing; the fixture cannot seat and the unit cannot be tested, so the station jams.
    • Failure Analysis: Cross-checked 5 failing and 5 passing units: the gap follows the AMPB shield plate lot, not the fixture. Supplier SG-2607 measured 0.42 mm above nominal on 3 of 3 sampled plates.
    • Root Cause / Leading Hypothesis: Leading hypothesis, not yet proven: a worn stamping die at the supplier drove the plate above the upper tolerance from 2026-11-05 onward.
    • Containment Action(s): 4,820 pcs of lot SG-2607 quarantined in VN and CQ; 100% gap check added at incoming and at the FATP station; 32 suspect units segregated for teardown.
    • Corrective Action(s): Supplier to re-stamp lot SG-2607 with a verified die; replacement material to VN with ETA 2026-11-19; die measurement report requested.
    • Preventive Action(s): Die wear counter and a first-article gap check at each supplier lot start; lot SG-2607 traced end to end.
    • Next Steps & Dates: Die measurement report from supplier - DRI Henry Zeng - ETA 2026-11-15. Replacement material to VN - DRI Henry Zeng - ETA 2026-11-19.
    • Factory Risk Assessment: Line-stop risk on AMPB from 2026-11-17 if the replacement material slips; MLB is not affected.
    • Field Exposure Risk Assessment: No unit with lot SG-2607 has shipped to a customer.