Data cut-off: 2026-11-20 14:00 (VN) · Phase: DVT
OVERALL STATUS: YELLOW
1. Overall status and executive summary
Overall quality status is Yellow. FATP yield remains below the 97.5% target, with the primary loss at ACT.
- LCM Line-stop Issue: All 4 LCM issues at VI1 are analysed to a clear failure direction (ZIF pin damage from insertion force, PI/ink contamination at the BTB, wrong-direction FPC insertion, BTB deformed before assembly). Containment is in place - the IQC CCD re-check on 11/20 closed the IQC-escape question - and the preventive action is a new pre-FATP line-in bending visual inspection plus cosmetic control of this material before it reaches the line.
- Yield Target: Current cumulative FATP yield rate isn't hitting the 97% target yet, and the main loss is in ACT.
- Build and lines: 1 Auto line is active and is certified by line audit.
- Pre-CET: Pre-CET is scheduled for testing on 12/5, and the test report should be ready by 12/9.
2. Factory data ( Main Build) cut off 2026-11-20 14:00 (VN)
OBA
- Pre-seal: Cum. inspected 3 pcs, passed 0 pcs, pass rate: 0.00%.
- Post-seal: No main build unit input as of data cut-off.
- There are 11 SW issues still open right now (1 new catches on DVT and 10 known SW issues).
SMT MLB Production Data
- Cumulative actual Input/Output: 2,535 / 2,498 pcs. Cum. FPY: 99.59% vs target: 98.50%, Cum. RPY: 99.68%.
SMT AMPB Production Data
- Cumulative actual Input/Output: 3,639 / 3,159 pcs. Cum. FPY: 100.00% vs target: 98.50%, Cum. RPY: 100.00%.
FATP Production Data
- Cumulative actual Input/Output: 330 / 6 pcs. Cum. FPY: 62.35% vs target: 97.50%, Cum. RPY: 64.62%.
3. DVT highlight issues — 0 blocker, 2 critical
Issue 1 : MIRAMAR-1880 — Horizontal convergence angle failure found at ACT. 1.02% [3F/295T]
- Level: Critical
- Status: On-going · DRI: Ethan Su (Huaqin) · JIRA Ticket(s): MIRAMAR-1880
- Description: Horizontal convergence angle failure found at ACT
- Customer Failure Mode: Camera captures show visible tilt/distortion in images.
- Failure Analysis: Phenomenon: Horizontal convergence angle measured 4.15 vs spec [-3,+3]; test image shows camera tilt; teardown mechanism: camera rubber cover severely tilted and pressed by mic bracket, causing significant rightward camera tilt. LCM not misaligned and gap/step within spec; reassembly with rubber repositioned and mic bracket removed passes ACT.
- GVW62R016455009A
- 2 GVW62S0064660088
- GVW62R01645500E5
- Current Jira failure rate: 1.02% [3/295].
- Root Cause / Leading Hypothesis: Mechanical assembly defect: camera rubber cover severely tilted and pressed by the mic bracket, causing camera optical axis misalignment and rightward camera tilt; LCM and gap/step measurements were within spec, and reassembly with proper rubber positioning/mic bracket clearance passed.
- Containment Action(s): Emphasize operator thoroughness during camera and rubber installation at FATP station.
- Corrective Action(s): Proposed permanent fix: change camera protective film to transparent material so operators can more easily verify camera rubber position.
- Preventive Action(s): Add FATP visual inspection/work-instruction check for camera rubber seating under transparent protective film and verify mic bracket clearance to prevent pressing the camera rubber cover.
- Next Steps & Dates: Validate transparent camera protective film change and update FATP inspection work instruction
- Evaluate mic bracket clearance/assembly design to prevent pressing the camera rubber cover
- Complete FA on all affected SNs and confirm failure mechanism repeatability
- Monitor ACT horizontal convergence angle failure rate and implement 100% sorting/hold if rate increases
- Factory Risk Assessment: Moderate: Jira failure rate is 1.02% [3/295] at ACT, and containment currently relies on operator thoroughness re-emphasis;
- Field Exposure Risk Assessment: Low if all units undergo ACT horizontal convergence angle screening prior to shipment; escaped units could show tilted/distorted camera images showing as ACT failure.
Issue 2 : Miramar-1890~1893 — LCM issues found at VI1 caused a line stop. (4F/255T at the line-stop window)
- Level: Critical · Risk: YELLOW
- Status: Resolved · JIRA Ticket(s): Miramar-1890~1893
- Description: Caught 4 LCM abnormalities at VI1, which triggered a line stop.
- >
- GVW62S0064660060 - Miramar-1890 - No power-on (no display).
- GVW62R016455006B - Miramar-1891 - No power-on (no display); SPI communication abnormal.
- GVW62R01645500BN - Miramar-1892 - No touch response.
- GVW62R0164550089 - Miramar-1893 - No power-on (no display); BTB deformation.
- Customer Failure Mode: Users might run into a black screen or a touch that doesn't respond.
- Failure Analysis: >
- GVW62S0064660060 - ZIF socket internal pins broken; FPC damaged. IQC LCD functional test PASS (retest PASS); display OQC pictures show no pin deformation; supplier FPC 0.198 / 0.203 / 0.205 mm against a fail sample of 0.21 mm, all within 0.20±0.02 mm.
- GVW62R016455006B - Foreign objects in the BTB connection: fragments of PI and ink scratched/pressed onto the FPC, so the contact path is compromised (SPI abnormal).
- GVW62R01645500BN - Serious slanted scratch mark on the connector: the operator assembled the FPC in the wrong direction. Reassembling with the FPC corner tilted the wrong direction did not reproduce no-touch.
- GVW62R0164550089 - LCM FPC BTB deformation; the AOI capture from before assembly already shows the BTB deformed.
- Root Cause / Leading Hypothesis: >
- GVW62S0064660060 - Insertion force during assembly, or a connector design tolerance mismatch. The IQC-escape route is closed: the IQC CCD inspection on 300 pcs LCM PCB (done 11/20) found no abnormality, and both IQC and supplier OQC passed.
- GVW62R016455006B - PI and ink fragments were already on the FPC before the connector was assembled, and they were scratched/pressed into the BTB interface, breaking the contact path. The vendor re-check confirms the probe-pin contact does not press the LCM_BTB edge, so the contamination comes from the material, not the assembly station.
- GVW62R01645500BN - The operator assembled the FPC in the wrong direction and inserted it repeatedly, which scratched the connector.
- GVW62R0164550089 - The BTB was already deformed before assembly (AOI evidence). The bending station is cleared: the vacuum holder alarms on misplacement, 5x simulated bending caused no BTB damage, and the bonding device only picks the unit up to photograph it with no pressing. The deformation is therefore introduced by handling of the bare LCM material upstream of the line.
- Containment Action(s): >
- GVW62S0064660060 - IQC CCD inspection on 300 pcs LCM PCB: no abnormality, done 11/20. Warehouse 300 pcs full CCD re-check, cut-off 11/19 (Chen Wei / Wang Song / Nong Thi Hoai).
- GVW62R016455006B - Vendor 200% CCD OQC on the BTB/ZIF area (XY), and strengthened cosmetic control of this material before the FATP line-in so contaminated units cannot enter the line.
- GVW62R01645500BN - OP training on the correct insertion direction, then re-checked on the line.
- GVW62R0164550089 - Strengthened cosmetic control (bending/deformation and residual glue on the BTB surface) before the FATP line-in; suspect units are held and screened by AOI before assembly.
- Corrective Action(s): >
- GVW62S0064660060 - PE to reproduce with forceful insertion (Duong Thieu Vi); update the connector drawing to show the open and closed state and confirm the connector type selection; full CCD inspection on all 3,000 PVT parts (Wang Song / Nong Thi Hoai).
- GVW62R016455006B - Vendor to remove the PI/ink fragment source from the FPC process (process correction and cleanliness control), and IQC incoming inspection criteria for FPC/BTB cleanliness to be updated; 200% CCD OQC stays until the source is closed.
- GVW62R01645500BN - Three actions implemented: keep the FPC parallel to the screen face in the thickness direction; insert perpendicular to the connector, never diagonally along its length; never force a stiff insertion - re-align first (Li Hao).
- GVW62R0164550089 - Strengthened cosmetic control and handling discipline for the bare LCM material before the FATP line-in; the suspect material is segregated and screened by AOI, so a deformed BTB cannot be assembled.
- Preventive Action(s): >
- GVW62S0064660060 - Drawing-level definition of the open and closed state so the wrong connector type cannot be selected; full CCD on incoming PVT material.
- GVW62R016455006B - New pre-FATP line-in bending visual inspection on this material, plus cosmetic control of the BTB surface (deformation and residual glue) before the line is fed.
- GVW62R01645500BN - Same OP training rolled out on the whole line; insertion direction called out in the SOP.
- GVW62R0164550089 - New pre-FATP line-in bending visual inspection on this material, so any deformation is caught before assembly.
- Next Steps & Dates: >
- GVW62S0064660060 - PE to reproduce with forceful insertion (Duong Thieu Vi); connector drawing update and type-selection confirmation; full CCD inspection on all 3,000 PVT parts; result reported in the next daily report.
- GVW62R016455006B - Run the pre-FATP line-in cosmetic check on the next lot and confirm the 200% CCD OQC still picks the NG out; vendor closes the PI/ink source and reports back.
- GVW62R01645500BN - File the OP training record (Li Hao) and verify no recurrence in the next build.
- GVW62R0164550089 - Run the new pre-FATP bending visual inspection on the next lot and track the defect rate; report the result in the next daily report.
- Factory Risk Assessment: Issue screening is in force (IQC CCD on 300 pcs clean; vendor 200% CCD OQC for the BTB/ZIF area; pre-FATP line-in cosmetic and bending checks).
- Field Exposure Risk Assessment: Low: this is a DVT build, all suspect material is screened before the FATP line-in and the escape paths (IQC CCD, supplier 200% CCD OQC, AOI) are in place; no field return exists.