MDA failure records: 1 unit at VI1 · Jira failure rate 0.24% (1/410).
SN GVW62R01645500BN — Real Fail / Under FA(UFA)
Analysis: operator inserted FPC at angle along length rather than perpendicular to connector, with repeated insertion attempts causing connector damage and loss of electrical contact. Corrective Action Implemented three corrective actions: (1) maintain FPC direction parallel to screen during assembly; (2) insert FPC perpendicular to connector, not at angle along length; (3) if insertion feels hard, do not f